Filter
Outdoor Sensors
WSA
Weatherproof humidity and temperature sensor for outdoor applications. The radiation shield protects the sensors from rain, hail and radiated heat. The curved shape of the plates ensure that air can move across the sensors to keep radiated temperature from rooftops and other surrounding surfaces away and guarantee proper measurement. Typical applications are meteorology, greenhouses and industrial environments.
Application/type | Outdoor sensor |
---|---|
Purpose | Measure values |
Measured values | temperature, relative humidity, absolute humidity, enthalpy, dew point |
Interface | LoRaWAN® (868 MHz), RS485 Modbus, RS485 BACnet, Passive, Active, 0..5 V, 0..10 V, 4..20 mA |
Configuration | USEapp, uConfig, BUS, jumper, DIP switches, LoRaWAN® Downlink, (depending on type) |
Sensor | NTC10k, PT1000 DIN cl. B, Ni1000 DIN cl. B, PT1000 1/3 DIN, PT100 DIN cl. B, Ni1000TK5000, PT100 1/3 DIN, NTC10k Precon, NTC10K Carel, NTC1,8K, NTC5K, NTC20K, LM235Z, DS18B20 1-wire, additional passive sensor |
Output voltage | 2x 0..10 V or 0..5 V, adjustable via jumper, live-zero configuration via app or uConfig, min. load 10 kΩ |
Output current | 2x 4..20 mA, max. load 500 Ω |
Output switch contact | 2x floating contact NO for 24 V ~ or 24 V = / 3 A |
Network technology | RS485 Modbus, RS485 BACnet (MS/TP), LON FT (free topology) |
Radio technology | LoRaWAN® (868 MHz) |
Data transmission | bidirectional, RTU, half-duplex, baud rate 9.600, 19.200, 38.400 or 57.600, parity: none (2 stop bits), even or odd (1 stop bit) |
Operating range temperature (°C) | -20..+70 |
Output signal temperature | scaling analogue output, -20..+80 °C (default setting), selectable from 4 temperature ranges -40..+60 | 0..+50 | -20..+80 | -15..+35 °C, adjustable at the transducer, optionally configurable, depending on used sensor |
Operating range humidity | max. 85% rH short term condensation |
Accuracy temperature | ±0,3 K (typ. at 21 °C), within default measuring range, ±0,3 K (typ. at 0 °C), ±0,4 K (typ. at 0 °C), ±0,2 K (typ. at 25 °C, temperature dependend), potentiometer for offset adjustment, offset setting via app or uConfig |
Measuring range humidity | 0..100% rH non-condensing, 0..85 KJ/kg enthalpy, 0..50 | 0..80 g/m³ absolute humidity, 0..+50 | -20..+80 °C dew point |
Accuracy humidity | ±2% between 10..90% rH (typ. at 21 °C), potentiometer for offset adjustment, offset setting via app or uConfig |
Power supply | 15..24 V = (±10%) SELV, 15..35 V = SELV, 24 V ~ (±10%) SELV, 19..29 V ~ SELV |
Power consumption | typ. 0,4 W (24 V =), max. 1 W (24 V =), max. 2,5 W (24 V =), 0,8 VA (24 V ~), 4,3 VA (24 V ~) |
Material in touch with media | Pipe, Ø=19,5 mm, PA6, with filter stainless steel wire mesh, weather protection PC, stainless steel |
Display | LCD 29x35 mm, RGB backlight, with traffic light function, threshold values configurable, optionally configurable via app or uConfig |
Enclosure | USE-S, impact- and shock-resistant enclosure with quick-release cover, PC, USE-M, impact- and shock-resistant enclosure with quick-release cover, PC, with weather protection |
Colour | pure white, transparent cover |
Protection (IP) | IP65, according to EN 60529 |
Connection | removable cable entry flextherm M20 for wire Ø=4,5..9 mm, removable cable entry M25 with fourfold cable entry for wire with max. Ø=7 mm, removable plug-in terminal, max. 2,5 mm², BUS max. 1,5 mm², relay max. 1,5 mm² |
Mounting | mounting at the wall or at a pole |
Delivery content | incl. mounting set (screws and accessories) |
Packaging length (mm) | 170 |
Packaging width (mm) | 120 |
Packaging height (mm) | 265 |
Packaging | case packaging |
Device length (mm) | 190 |
Device width (mm) | 130 |
Device height (mm) | 250 |
Option enclosure | LCD 29x35 mm, RGB backlight |
No BIM data available
Vorschau | Name |
---|---|
WSA_Header.jpg |
Vorschau | Name |
---|---|
EU_Konformitätserklärung_WSA+_xxxx.pdf | |
EU_Konformitätserklärung_WSA_RS485_Modbus_Bacnet.pdf | |
UKCA_Declaration of Conformity_WSA+_xxxx.pdf |
No tender texts available